Subgrade compaction is often treated as a single uniform process, but in reality the subbase, roadbed, and fill layers have different requirements for rollers. For the same single-drum vibratory roller, the usable amplitude and frequency settings differ between thick and thin layers, and the excitation force cannot always be understood as the maximum value. What readers really need to determine is: how thick their layer is, what material it uses, what compaction target must be achieved, and then decide which vibration parameter setting to use.
First distinguish the layered task, then look at equipment parameters
Subgrade is usually divided along the depth direction into several fill layers or structural layers, each with different material particle size, moisture condition, and design thickness. Thick fill layers require greater vibration energy to transmit downward, while thin layers or areas near the top of the roadbed place more emphasis on surface smoothness and uniformity; excessive vibration may cause surface loosening or disturbance to adjacent structures. Therefore, when selecting equipment, taking "how much maximum centrifugal force this machine has" as the sole basis is insufficient. A more reasonable approach is to see whether the vibration settings it provides can cover the needs of different layers.
Taking the single-drum vibratory roller in the site data as an example, the parameters of this type of equipment are usually given in two settings rather than a single value. Below, its published parameters are matched to layered tasks for reference only; this does not mean that a certain degree of compaction can be achieved in any soil layer.

What working conditions do the two vibration parameter settings correspond to?
| Parameter | Verified value | Relationship to layered tasks |
|---|---|---|
| Operating weight | 14000 kg | Determines the basic magnitude of static compaction effect and affects stability during thin-layer finishing |
| Vibration frequency | 30 / 34 Hz | Two frequency settings; low-frequency and high-frequency settings correspond to different layer and travel speed arrangements |
| Amplitude | 1.85 / 0.83 mm | High-amplitude setting is more suitable for thick layers; low-amplitude setting is more suitable for thin layers or near the finished surface |
| Centrifugal force | 315 / 190 kN | Linked to amplitude settings; use the high value for thick layers and the low value for thin layers |
| Drum width | 2130 mm | Affects overlap and working strip width, and is related to organizing compaction passes by layer |
| Static linear load | 391 N/cm | Linear load under static compaction, used to judge suitability for static finishing of thin layers |
| Gradeability | 45% | Related to subgrade fill slopes and temporary access road traffic conditions |
The judgment sequence that can be read from this set of data is: first determine by layer position whether to use the high-amplitude or low-amplitude setting, then look at the combination of frequency and centrifugal force under the corresponding setting, and finally arrange construction based on layer thickness, material, and number of passes. The two settings have clear values respectively; the maximum value of 315 kN cannot be directly applied to all layers, nor should the low-amplitude setting be understood as "insufficient capability," since it has its own place in thin layers and finishing stages.
Judgment path advancing by layer position
Thick fill layers: prioritize the high-amplitude setting
Thicker fill layers require sufficient transmission depth of vibration energy, so the setting of 1.85 mm amplitude and 315 kN centrifugal force is usually considered first. Whether to use 30 Hz or 34 Hz at this time must be confirmed through on-site trial compaction in combination with travel speed and actual layer thickness; the data itself does not provide a recommended speed or number of passes for a certain soil layer.

Thin layers and areas near the top of the roadbed: switch to the low-amplitude setting
When the layer becomes thinner or is near the finished surface, the setting of 0.83 mm amplitude and 190 kN centrifugal force is more worth considering. At this time the equipment still provides a static compaction basis with its 14-ton operating weight, and the static linear load of 391 N/cm can serve as a reference for judging the suitability of static finishing on thin layers. Whether to turn off vibration and how many passes to use still must be determined by on-site trial sections.
Slopes and site conditions: check traffic conditions
The 45% gradeability is a reference value given in the data; whether safe operation is actually possible also depends on slope material, moisture condition, and operating conditions. Before working on slopes or temporary access roads, traffic and anti-slip conditions should be verified as separate items; this value alone cannot be used to judge that any slope is usable.

Which conditions the data cannot determine for you
- The number of compaction passes and travel speed corresponding to specific soils (cohesive soil, sandy soil, gravel fill);
- The matching relationship between each layer thickness and amplitude setting, which requires trial section verification;
- The conclusion on whether the required degree of compaction can be achieved, which must be provided by on-site testing;
- Vibration distance restrictions for adjacent structures and pipelines in different projects;
- The actual availability and maintenance arrangements of the equipment, which should be formulated according to the manual and site conditions.
These matters have no uniform answer and can only be confirmed item by item under project conditions. Treating them as prerequisites for selection can reduce rework more effectively than simply comparing parameter values.
Information to be clarified together before purchase
If you plan to request a quotation for this type of 14-ton single-drum vibratory roller, it is recommended to also provide: the layered structure and design thickness of each layer, the main fill material type and moisture condition, working strip width and daily compaction area, site slope and transport access conditions, shift arrangements, and whether municipal roads or rural roads and other scenarios also need to be considered. On the equipment side, it is necessary to check whether the vibration setting configuration, drum width, and linear load match the above layered tasks, as well as the instructions on vibration operation and maintenance inspection in the accompanying documents. Parameters are only the starting point; whether the machine can be used on a certain layer still depends on on-site trial sections and test results.